Acoustigard - Acoustic Glasswool

Acoustigard is a glasswool fibre insulation specifically engineered to reduce sound transmission in walls and ceilings. The product comes in a range of densities and is also certified as a thermal insulation for non-combustible external walls.

Applications:

  • Partition walls
  • Intertenancy walls
  • External walls
  • Services
  • Ceilings

For product and sales support please call 1300 760 233 or send our team an email by clicking EMAIL ENQUIRY

Overview

Acoustigard

Bradford Acoustigard Partition Batts and Rolls are manufactured by spinning molten glass into fine wool-like fibres, containing up to 65% recycled glass content. These inorganic, non-combustible fibres are bonded together using a thermosetting resin and the product can be identified by its golden appearance and is supplied un-faced.

Features and Benefits

Acoustigard

  • Excellent acoustic properties - helps reduce sound transmission through wall systems
  • Non combustible fibre - does not add to the fuel load in the building
  • Friction fit to suit commercial stud spacing – no stapling required
  • All products thermally rated to AS4859.1 to control performance characteristics 
  • Compression packaged - easily handled and stored on-site improving m2 per movement on site.
  • Made from a safe to handle Fibre Bio-Soluble (FBS-1) formulation
  • Made in Australia for Australian conditions

Product Test Data

Density Thickness Frequency
kg/m3 (mm) 125 250 500 1000 2000 4000 5000 NRC aw
11 75mm 0.26 0.63 0.97 0.87 0.92 0.97 0.95 0.85 0.90
14 75mm 0.26 0.71 1.03 1.00 0.95 0.99 0.97 0.90 0.95

Physical Properties

Maximum Service Temp 350°C
Thermal Compliance AS/NZS4859.1 Materials for the thermal insulation of buildings Complies
Moisture Absorption When left in a controlled atmosphere of 50°C and 95% relative humidity for four days Less than 0.2% by volume
Fire Hazard Properties When tested in accordance with AS1530.3:1999 Ignitability: 0
Spread of Flame: 0
Heat Evolved: 0
Smoke Developed: 1
Combustibility When tested in accordance with
AS1530 Part 1:1994
Non-combustible
Applications
Specifications

Insulation for Non-Combustible Walls

The use of non-combustible components in high-rise external facades is critical in preventing the vertical spread of fire, this includes insulation.